Products

Defi-Link Display

Defi-Link Display is a multipurpose monitor which provides information on speed, oil temperature, water temperature, oil pressure, fuel pressure, and exhaust temperature by connecting to the Defi-Link Control Unit II or the Defi-Link Control Unit(end of sale).

Defi-Link Display can be connected to Defi-Link Meters and Defi-Link Meter BFs by using the DAISY CHAIN wiring system.

Parts No.DF05101

Defi-Link Control Unit II or Defi-Link Control Unit is necessary to operate Defi-Link Display.

The production of Defi-Link Display has been ended in April, 2010.

  • An easily recognizable graphic on each setting screen helps guide easy setting of warnings for Defi-Link Meters and Step Graph(Setting Assistance function).
  • The display uses OLED(organic light emitting diode).
  • OLED is an advanced display which is self light emissive, high contrast, high response, low power consumptive, and large view angle. It uses optimal technology for instant readability without afterimages of flicker even when seen from the passenger’s seat.
  • Real-time digital information includes speed, oil temperature, water temperature, oil pressure, fuel pressure and exhaust temperature. Sensor sets need to be purchased separately to display the information on pressures and temperatures.
  • Vehicle performance data and peak values are placed in memory for 3 minutes, allowing examination of data after running the vehicle.
  • *Defi-Link Control Unit II has a 3 minute memory. Defi-Link Control Unit has a 40 second memory.
  • When the RPM signal wire is connected to Defi-Link Control Unit II or Defi-Link Control Unit, 2 warning levels can be set in addition to the warning setting made by Control Unit II or Control Unit, enabling the setting of a total of 3 warning levels(Tachometer Triple Warning Mode).
  • When the water temperature sensor is connected, the warm-up condition can be monitored. A graphic animation plays after the ignition is turned on or off(Opening Mode/Ending Mode).
  • The Warning LED lights when the set warning value is exceeded for oil temperature, water temperature, exhaust temperature and engine RPM. The Warning LED lights when measured value drops below the set warning value for oil pressure and fuel pressure.
  • Trouble locations are shown by graphics so that connection problems can be quickly corrected(Self-Diagnosis function).
  • The structure of the mounting base allows height and angle adjustment so that it can match the shape of the instrument panel.
  • The Defi-Link Indicator(sold separately) can be connected to the display.
  • To display pressures and temperatures, sensor sets needs to be purchased separately. Defi-Link Display displays only speed without installing sensors.

SIZE in mm(inches)

SIZE in mm(inches)

Part Names

name

Other Specification

Power supply voltage 8.5V to 13.5V DC
(for use 12V Vehicles Only, voltage supplied by Defi-Link Control Unit II or Defi-Link Control Unit)
Current consumption IGN ON: Max. 0.2A
ILM ON: Max. 0.2A
Display Range Speedometer
0 to 400km/h, 0 to 240MPH
Oil Temperature
51 to 150℃, 123 to 302°f
Water Temperature
21 to 120℃, 69 to 248°f
Oil Pressure
0 to 1,000kPa, 0 to 145PSI
Fuel Pressure
0 to 600kPa, 0 to 87PSI
Exhaust Temperature
210 to 1,100℃, 400 to 2,010°f
Corresponding
Speed Pulse
2, 4, 8, 16, Pulse Free(1,274pulse/km ~ 16,562pulse/km,
2,051pulse/mile ~ 16,665pulse/mile)
NOTE *This products is for only on vehicles with a 12V electrical system. Never use this product on 24V vehicles.
*Products can not be installed in altered vehicles.
*To install pressure or temperature sensors, proper sensor attachments are necessary.

Parts list

Part Name Quantity
Defi-Link Display 1
Installation Stay 1
Meter Wire(25cm) 1
Speed Signal Wire(2m) 1
Set Screw 1
Parts Set
(double-sided tape, buffer, mounting bracket,
M4 bolt & nut, washer)
1
Operations Manual 1
Solderless Connector 1

OPTIONAL PARTS

To display pressures and temperatures, sensor sets needs to be purchased additionally.
Sensor sets include the sensor and the sensor wire.

Item Model Number
Defi-Link OIL PRESS. Sensor Set PDF00713SS
Defi-Link FUEL PRESS. Sensor Set PDF00806SS
Defi-Link OIL TEMP. Sensor Set PDF00908SS
Defi-Link WATER TEMP. Sensor Set PDF01006SS
Defi-Link EXHAUST TEMP. Sensor Set PDF01114SS

COMMERCIAL PARTS WHICH NEED TO BE PURCHADED

Commercial parts need to be purchased as follows:

Sensors which are installed Part Name
Oil pressure Sensor attachment, Teflon tape
Fuel pressure Three-way joint, hose union, Teflon tape
Oil temperature Sensor attachment, Teflon tape
Water temperature 2 Clamps, Sensor attachment, Teflon tape

Operation Status Transition Diagram

Operation Status Transition Diagram
  • Triple Warning Mode is not available when connected to Defi-Link Meter BF.
  • Only Speed Mode is available if there are no sensors connected to the Defi-Link Control Unit II or Defi-Link Control Unit. In addition, Peak Mode and Replay Mode will not function.
  • Only Speed Mode is available if there are no sensors connected to the Defi-Link Control Unit II or Defi-Link Control Unit. In addition, Peak Mode and Replay Mode will not function.
  • Be sure to connect the speed signal wire when using this product.

Modes

Set up Mode

Allows setting units and display data parameter.

Warning Set up mode

Allows setting of warnings for meters connected to Defi-Link Control Unit II or Control Unit.

Warning Set up mode

Gauge mode

Displays actual vehicle data and speed data for meters connected to Defi-Link Control Unit II or Defi-Link Control Unit.

Peak memory

Peak memory

Memory replay

Memory replay

Speed mode

Displays the vehicle speed.

Driving Peak Memory replay
Driving Peak Memory replay

Triple Warning mode

Displays a warning when the Tachometer exceeds the engine RPM set warning value.

No warning Warning1
(over 9,000 RPM)
Warning2
(over 10,000 RPM)
No warning Warning1 (over 9,000 RPM) Warning2 (over 10,000 RPM)

Replay & peak display

Records vehicle data for meter connected to Defi-Link Control Unit II or Defi-Link Control Unit or it replays the recorded data or displays data peaks.

Record or replay Peak
Record or replay Peak

Special display mode

Appears when speed is 0km/h or 0MPH for more than 10 seconds.

Special display mode

Warm-up mode

Monitors water temperature until it reaches a set value.

Warm-up Warm-up done
Warm-up Warm-up done

Self diagnosis mode

Displays serial errors, opens and shorts for each sensor of meters connected to Defi-Link Control Unit II or Defi-Link Control Unit when ignition is on.

serial error short-circuit disconnected
serial error short-circuit disconnected

Opening/Ending mode

Appears when the ignition is turned on and off.

IGN ON
IGN ON