Defi-Link Display - HOW TO OPERATE -
Set Up Mode
This screen allows setting units and display data parameters.

Be sure to make preparatory settings. The unit will not operate properly without settings being made.

When changing the factory settings shown below, pressing the SET UP button after the Opening Mode has completed will bring up the setting mode for speed units.
Item
Setting Range
Display Units
Factory Setting
1 Speed Units km/h, MPH km/h or MPH km/h
2 Pressure/Temperature Units kPa/oC, PSI/oF kPa/oC or PSI/oF kPa/oC
3 Speed Pulse 2, 4, 8, 16, FREE - 4 pulse
4 Special Display ON, OFF - ON
5 Warm-up 20 to 120oC, 68 to 248oF oC or oF 40oC
6 Gauge Display Single, Dual - single
7 Tachometer Warning1 1,000 to 11,000RPM RPM 7,000RPM
Tachometer Warning2 Warning 1 to 11,000RPM RPM 8,000RPM
*In Set Up Mode, the item to be set changes each time the ENTER button is pressed. When adjustment of a particular setting is not needed, press the ENTER button to skip that item.



1. Setting Speed Units
Use the MODE SELECT button to select Speed Units, then press ENTER to set the desired units.
2. Setting Pressure / Temperature Units
Use the MODE SELECT button to select the speed pulse number, then press ENTER to set the selection.

3. Setting Speed Pulse
Use the MODE SELECT button to select the speed pulse number, then press ENTER to set the selection.


Speed Pulse Number: The speed pulse number differs by model of vehicle. Consult your local car dealer if you are not certain of the speed pulse number for your vehicle.
Pulse Free Setting: For vehicles having a speed pulse outside 2, 4, 8, 16 pulse, the speed pulse can be set by switching to the "Free" screen and then by pressing and holding the ENTER button while the vehicle is moving at 60km/h or 40MPH. After 2 seconds of holding the button, the screen will change and the speed pulse will be set.

*If the speed units are changed while using Pulse Free, it is necessary to repeat the pulse free setting steps.
4. Setting special Display
Use the MODE SELECT button to select the special display setting, then press ENTER to set the selection.

5. Setting Warm-up (only available when water temperature sensor is connected)
Use the MODE SELECT button to select ON or OFF, then press ENTER to set the selection.

*When On is selected, each time the MODE SELECT button is pressed, the temperature value setting will increase by 1oC and each time the button is pressed and held, the value will increase by 5oC. When the desired temperature value is reached, it is set by pressing the ENTER button.
6. Setting Gauge Display
Use the MODE SELECT button to select display data format, then press ENTER to set the selection.
7. Setting Tachometer Warning1 and 2

Use the MODE SELECT button to select warning value, then press ENTER to set the selection.
Each time the MODE SELECT button is pressed, the value will increase by 100RPM.

Each time the MODE SELECT button is pressed and held, the value will increase by 500RPM.


CLOSE