| Set Up Mode |
| This screen allows setting units and display data parameters. |

 |
Be sure to make preparatory settings.
The unit will not operate properly without settings being made. |
When changing the factory settings shown below, pressing the SET UP
button after the Opening Mode has completed will bring up the setting
mode for speed units. |
|
Item
|
Setting
Range
|
Display
Units
|
Factory
Setting
|
| 1 |
Speed Units |
km/h, MPH |
km/h or MPH |
km/h |
| 2 |
Pressure/Temperature Units |
kPa/oC, PSI/oF |
kPa/oC or PSI/oF |
kPa/oC |
| 3 |
Speed Pulse |
2, 4, 8, 16, FREE |
- |
4 pulse |
| 4 |
Special Display |
ON, OFF |
- |
ON |
| 5 |
Warm-up |
20 to 120oC, 68 to 248oF |
oC or oF |
40oC |
| 6 |
Gauge Display |
Single, Dual |
- |
single |
| 7 |
Tachometer Warning1 |
1,000 to 11,000RPM |
RPM |
7,000RPM |
| Tachometer Warning2 |
Warning 1 to 11,000RPM |
RPM |
8,000RPM |
|
*In Set Up Mode, the item to be set changes each time the ENTER
button is pressed. When adjustment of a particular setting is not
needed, press the ENTER button to skip that item.
|
| 1. Setting Speed Units |
Use the MODE SELECT button to select Speed Units, then press
ENTER to set the desired units.
|
 |
|
| 2. Setting Pressure / Temperature
Units |
Use the MODE SELECT button to select the speed
pulse number, then press ENTER to set the selection.
|
 |
|
| 3. Setting Speed Pulse |
Use the MODE SELECT button to select the speed
pulse number, then press ENTER to set the selection.
|
 |
| Speed Pulse Number: |
The speed pulse number differs by model of vehicle.
Consult your local car dealer if you are not certain of the
speed pulse number for your vehicle. |
| Pulse Free Setting: |
For vehicles having a speed pulse outside 2, 4,
8, 16 pulse, the speed pulse can be set by switching to the
"Free" screen and then by pressing and holding the
ENTER button while the vehicle is moving at 60km/h or 40MPH.
After 2 seconds of holding the button, the screen will change
and the speed pulse will be set.
*If the speed units are changed while using Pulse Free, it is
necessary to repeat the pulse free setting steps. |
|
| 4. Setting special Display |
Use the MODE SELECT button to select the special
display setting, then press ENTER to set the selection.
|
 |
|
| 5. Setting Warm-up (only
available when water temperature sensor is connected) |
Use the MODE SELECT button to select ON or OFF,
then press ENTER to set the selection.
|
 |
*When On is selected, each time the MODE SELECT button is pressed,
the temperature value setting will increase by 1oC and each time the
button is pressed and held, the value will increase by 5oC. When the
desired temperature value is reached, it is set by pressing the ENTER
button.
|
| 6. Setting
Gauge Display |
Use the MODE SELECT button to select display
data format, then press ENTER to set the selection.
|
 |
|
| 7. Setting Tachometer Warning1
and 2 |
|
Use the MODE SELECT button to select warning value, then
press ENTER to set the selection.
Each time the MODE SELECT button is pressed, the value will
increase by 100RPM.
Each time the MODE SELECT button is pressed and held, the
value will increase by 500RPM.
|
|
|
CLOSE |